Input
Voltage | DC360V |
Current | 4.5A |
Maximum | ≤8A |
Input V | 260-560V |
Minimum V | 255V±5V |
Maximum V | 455570 |
Start Time | ≈0.8s @ VIN = 320V |
Output
Output V | 13.8V±1% |
Current | 110A |
Peak | 135A - 140A |
Power | 1500W |
Peak W | 1800W 6 minutes |
Efficiency | ≥95% |
Transient | ≤50ms |
Voltage reg | 1% |
Load reg | 1% |
Accuracy | ≤1% |
Steady Flow | ≤2% |
0 Leakage | ≤5mA |
0 Ripple | ≤276mV @ 12V |
Over V Prot | 15-16V @ 12V |
12V/24V enable voltage | 6-30V |
12V/24V enable current | ≤1mA |
Output harness | 25-30mm2 @ 12V |
Ground Resist | Resistance between ground and heatsink less than 100 milliohms, test current 25A AC |
Working Temp | -30~60 ℃ |
Storage Temp | -40~90℃ |
Humidity | 5%~95% non-condensing |
IP rating | GB4208-2008 IP67 |
Test voltage | Withstands the test voltage shown in Table 1 with no corona, ionization, arcing or breakdown between test terminals |
Insulation resistance | At ambient temperature (23 ± 2) ℃ and relative humidity of 80% to 90%, not less than 2M Ω |
Noise | Distance 1.5m, A-weighted ≤55dB |
Electromagnetic Compatibility | Meets the GB / T 18655-2002 12 and 14 of the relevant requirements |
Reliability | MTBF 300,000 Hours |